INPUT DATA
Number of MPP trackers
|
2 |
---|---|
Max. input current (Idc max)
|
12 / 12 A |
Max. short circuit current, module array
|
18 / 18 A |
DC input voltage range (Udc min - Udc max)
|
80 - 1000 V |
Feed-in start voltage (Udc start)
|
80 V |
Nominal input voltage (Udc,r)
|
710 V |
MPP voltage range (Umpp min - Umpp max)
|
240 - 800 V |
Usable MPP voltage range | 80 - 800 V |
Number of DC connections | 2 + 2 |
Max. PV generator power (Pdc max)
|
7,5 kWpeak |
OUTPUT DATA
AC nominal output (Pac,r)
|
5000 W |
---|---|
Max. output power (Pac max)
|
5000 VA |
AC output current (Iac nom)
|
21,7 A |
Grid connection (Uac,r)
|
1~ NPE 220/230 V |
AC voltage range (Umin - Umax)
|
180 - 270 V |
Frequency (fr)
|
50 / 60 Hz |
Frequency range (fmin - fmax)
|
45 - 65 Hz |
Total harmonic distortion
|
< 5 % 5="" %=""> |
Power factor (cos φac,r)
|
0,85 - 1 ind./cap. |
GENERAL DATA
Height | 645 mm |
---|---|
Width | 431 mm |
Depth | 204 mm |
Weight | 21,5 kg |
Degree of protection | IP 65 |
Protection class | 1 |
Overvoltage category (DC / AC) 1)
|
2 / 3 |
Night-time consumption | < 1 w 1=""> |
Inverter design | Transformerless |
Cooling | Regulated air cooling |
Installation | Indoors and outdoors |
Ambient temperature range | -40°C - +55°C |
Permitted humidity | 0 - 100 % |
Max. altitude 2)
|
4.000 m |
DC connection technology | 4x DC+ and 4x DC- screw terminals 2.5 - 16 mm² |
AC connection technology | 3-pin AC screw terminals 2.5 - 16 mm² |
Certificates and compliance with standards | DIN V VDE 0126-1-1/A1, IEC 62109-1/-2, IEC 62116, IEC 61727, AS 4777-2, AS 4777-3, G83/2, G59/3, CEI 0-21, VDE AR N 4105 |
EFFICIENCY
Max. efficiency (PV - grid) | 98,1 % |
---|---|
European efficiency (ηEU) | 97,1 % |
η at 5% Pac,r 3)
|
80,8 / 82,5 / 82,5 % |
η at 10% Pac,r 3)
|
89,6 / 94,8 / 93,1 % |
η at 20% Pac,r 3)
|
93,4 / 97,2 / 96,2 % |
η at 25% Pac,r 3)
|
94,1 / 97,3 / 96,8 % |
η at 30% Pac,r 3)
|
94,7 / 97,4 / 97,0 % |
η at 50% Pac,r 3)
|
95,8 / 97,9 / 97,7 % |
η at 75% Pac,r 3)
|
96,1 / 98,0 / 97,9 % |
η at 100% Pac,r 3)
|
96,2 / 97,9 / 97,9 % |
MPP adaptation efficiency | > 99,9 % |
PROTECTION DEVICES
DC insulation measurement | Yes |
---|---|
Overload behaviour | Operating point shift, power limitation |
DC disconnector | Yes |
Reverse polarity protection | Yes |
INTERFACES
WLAN / Ethernet LAN | Fronius Solar.web, Modbus TCP SunSpec, Fronius Solar API (JSON) |
---|---|
6 inputs and 4 digital inputs/outputs | Interface to ripple control receiver |
USB (type A socket) 4)
|
Data logging, inverter update via USB flash drive |
2x RS422 (RJ45 socket) 4)
|
Fronius Solar Net |
Signalling output 4)
|
Energy management (floating relay output) |
Datalogger and web server | Integrated |
External input 4)
|
S0 meter connection / Evaluation of overvoltage protection |
RS485 | Modbus RTU SunSpec or meter connection |