Description
Fronius Eco 27.0-3-S
Includes - SPD Type II, Data Manager & Stiring Fuses
THE COMPACT PROJECT INVERTER FOR MAXIMUM YIELDS.
TECHNOLOGY
SNAPINVERTER TECHNOLOGY
The SnapINverter generation of inverters features a simple, standardised mounting system, making installation and maintenance easier than ever. A special feature in the design of the device is that the connection area is separate from the power stage set compartment, with both being installed separately. The remarkably light connection area and all its cabling is fitted to the wall first, followed by the power stage set. The innovative hinged system makes installation and servicing extremely user-friendly. The inverter is simply placed in the wall bracket and then secured. This means that it is not necessary to remove the entire inverter for servicing, just the power stage set. All the cabling remains in place.
INTEGRATED DATA COMMUNICATION
We are the first inverter manufacturer to offer a data communication package with fully integrated datalogging, WLAN, Ethernet, energy management, web server and a range of interfaces. The inverter is connected to the internet by network cable or WLAN - without additional cabling - and grants you the perfect overview of how the PV system is operating. Connection to third-party components is provided by means of interfaces such as Modbus TCP SunSpec, Modbus RTU SunSpec or Fronius Solar API (JSON). The open interfaces can also be operated in parallel to the Fronius Solar.web.
SMART GRID READY
Fronius inverters are ready for the Smart Grid of tomorrow. The inverters are optimally equipped to meet the technical requirements of grids in the future. A series of smart functions, known as Advanced Grid Features, are built into the devices. They include a number of control functions for optimum feed-in of reactive power and effective power. These functions are designed to enable stable grid operation even when the PV system density is very high and to prevent unwanted interruptions to feed-in and associated yield losses if grid parameters exceed the thresholds. Fronius inverters therefore help to guarantee the yield of a PV system. Furthermore, where feed-in limits are imposed, Fronius inverters can provide dynamic feed-in control with self-consumption taken into account. Just connect the meter and set the feed-in limit!
DYNAMIC PEAK MANAGER
The Dynamic Peak Manager is a new MPP tracking algorithm that dynamically adapts its behaviour when searching for the optimal operating point. Its special feature is that the Dynamic Peak Manager automatically checks the entire characteristic curve on a regular basis and finds the global Maximum Power Point (GMPP), even in partial shade.
ZERO FEED-IN
Today, an increasing number of grid operators in various countries are stipulating a PV power feed-in limit as a precondition before a system is connected to the grid. With dynamic power reduction, Fronius is offering a solution for optimum feed-in management. The Inverter supplies the household consumers with energy first and then reduces the system Output to the maximum energy feed-in permitted by the grid operator. With Fronius inverters, zero feed-in is also a possibility thanks to this function, meaning that no PV power is fed into the grid. The relevant requirements of the grid operator can be fulfilled by simply enabling a Setting on the inverter's web interface.
ACTIVE COOLING
Active cooling technology relies on one or more fans, which not only avoid hot spots, but also regulate the air circulation inside the inverter, thus keeping the temperature of the power electronics low. This has a positive effect on the service life of the devices, optimises yields and reduces costs. At Fronius, active cooling is supplied as standard in all devices.
TECHNICAL DATA
INPUT DATA
Number of MPP trackers
|
1 |
---|---|
Max. input current (Idc max)
|
47,7 A |
Max. short circuit current, module array
|
71,6 A |
DC input voltage range (Udc min - Udc max)
|
580 - 1000 V |
Feed-in start voltage (Udc start)
|
650 V |
Nominal input voltage (Udc,r)
|
580 V |
MPP voltage range (Umpp min - Umpp max)
|
580 - 850 V |
Usable MPP voltage range | 580 - 850 V |
Number of DC connections | 6 |
Max. PV generator power (Pdc max)
|
37,8 kWpeak |
OUTPUT DATA
AC nominal output (Pac,r)
|
27 kW |
---|---|
Max. output power (Pac max)
|
27 kVA |
AC output current (Iac nom)
|
40,9 / 39,1 A |
Grid connection (Uac,r)
|
3~ NPE 400/230, 3~ NPE 380/220 V |
AC voltage range (Umin - Umax)
|
150 - 275 V |
Frequency (fr)
|
50 / 60 Hz |
Frequency range (fmin - fmax)
|
45 - 65 Hz |
Total harmonic distortion
|
< 2 % 2="" %=""> |
Power factor (cos φac,r)
|
0 - 1 ind./cap. |
GENERAL DATA
Height | 725 mm |
---|---|
Width | 510 mm |
Depth | 225 mm |
Weight | 35,7 kg |
Degree of protection | IP 66 |
Protection class | 1 |
Overvoltage category (DC / AC) 1)
|
2 / 3 |
Night-time consumption | < 1 w 1=""> |
Inverter design | Transformerless |
Cooling | Regulated air cooling |
Installation | Indoors and outdoors |
Ambient temperature range | -25°C - +60°C |
Permitted humidity | 0 - 100 % |
Max. altitude 2)
|
2.000 m |
DC connection technology | 6x DC+ and 6x DC- screw terminals 2.5 - 16 mm² |
AC connection technology | 5-pin AC screw terminals 2.5 - 16 mm² |
Certificates and compliance with standards | ÖVE / ÖNORM E 8001-4-712, DIN V VDE 0126-1-1/A1, VDE AR N 4105, IEC 62109-1/-2, IEC 62116, IEC 61727, AS 3100, AS 4777-2, AS 4777-3, CER 06-190, G99, UNE 206007-1, SI 4777, CEI 0-16, CEI 0-21 |
Refund Policy
Returns
Our policy lasts 30 days. If 30 days have gone by since your purchase, unfortunately we can’t offer you a refund or exchange.
To be eligible for a return, your item must be unused, in the same condition that you received it and in the original packaging unopened.
Several goods are exempt from being returned.
- Solar Cables
- Cut Cables
- Lead Acid Batteries
- Items on sale or clearance.
To complete your return, we require a receipt or proof of purchase and or the items serial number/s.
Returns need to be returned to the store or branch where purchased.
If the above conditions are not met SIWSA (PTY) reserves the right to reject any claims.
Returns will be credited at the prevailing price at the time or at the invoice price. Which ever is lower.
PLEASE NOTE: All return costs including delivery costs are for the account of the customer.
Refunds (if applicable)
Once your return is received (at your cost) and inspected, we will send you an email to notify you that we have received your returned item. We will also notify you of the approval or rejection of your refund.
If the return is approved, then your refund will be processed, and a credit will automatically be applied to your bank account via EFT, within 30 days.
Late or missing refunds (if applicable)
If you haven’t received a refund yet, first check your bank account again. If you’ve this and you still have not received your refund yet, please contact us at sales@siwsa.co.za
Sale items or Items marked for clearance are not illegible for returns.
Only regular priced items may be refunded.
Exchanges (if applicable)
We only replace items if they have been supplied defective or damaged. If you need to exchange an item for the same item, please notify us via email at sales@siwsa.co.za.
Return Shipping.
To return your product, you should return your product to: 169 Herman Street, Meadowdale, Johannesburg, 1614. Or the branch where the item was purchased.
You will be responsible for paying for your own shipping costs for returning your item. Shipping costs are non-refundable. If you receive a refund, the cost of return shipping will be deducted from your refund.
Depending on where you live, the time it may take for your exchanged product to reach you, may vary.